 TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
TOSHIBA InGaAP LED
TLRE50T(F),TLRME50T(F),TLSE50T(F),TLOE50T(F),TLYE50T(F), TLPYE50T(F),TLGE50T(F),TLFGE50T(F),TLPGE50T(F)
Panel Circuit Indicators
Unit: mm
Lead(Pb)-free products (lead: Sn-Ag-Cu) * 3 mm package * * * * * * * InGaAP technology All plastic mold type Transparent lens Line-up: 6 colors (red, orange, yellow, pure yellow, green and pure green) High intensity light emission Excellent low current light output Applications: message boards, security devices and dashboard displays
Lineup
Product Name TLRE50T(F) TLRME50T(F) TLSE50T(F) TLOE50T(F) TLYE50T(F) TLPYE50T(F) TLGE50T(F) TLFGE50T(F) TLPGE50T(F) Color Red Red Red Orange Yellow Pure Yellow Green Green Pure Green
InGaAlP
Material
JEDEC JEITA TOSHIBA Weight: 0.14 g
4-3E1A
For part availability and ordering information please call Toll Free: 800.984.5337 Website: www.marktechopto.com | Email: info@marktechopto.com
1
2005-09-13
TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
Maximum Ratings (Ta = 25C)
Product Name TLRE50T(F) TLRME50T(F) TLSE50T(F) TLOE50T(F) TLYE50T(F) TLPYE50T(F) TLGE50T(F) TLFGE50T(F) TLPGE50T(F) Forward Current IF (mA) 50 50 50 50 50 50 50 50 50 Reverse Voltage VR (V) 4 4 4 4 4 4 4 4 4 Power Dissipation PD (mW) 120 120 120 120 120 120 120 120 120 Operating Temperature Topr (C) Storage Temperature Tstg (C)
-40~100
-40~120
Electrical and Optical Characteristics (Ta = 25C)
Product Name TLRE50T(F) TLRME50T(F) TLSE50T(F) TLOE50T(F) TLYE50T(F) TLPYE50T(F) TLGE50T(F) TLFGE50T(F) TLPGE50T(F) Unit Typ. Emission Wavelength
d
630 626 613 605 587 580 571 565 558
P
(644) (636) (623) (612) (590) (583) (574) (568) (562) nm
20 23 20 20 17 14 17 15 14
IF 20 20 20 20 20 20 20 20 20 mA
Luminous Intensity IV Min Typ. IF 850 850 1530 1530 1530 850 476 272 153 mcd 1800 2200 3500 4500 3500 2500 1500 1000 600 20 20 20 20 20 20 20 20 20 mA
Forward Voltage VF Typ. Max IF 1.9 1.9 1.9 2.0 2.0 2.0 2.0 2.0 2.1 V 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 20 20 20 20 20 20 20 20 20 mA
Reverse Current IR Max VR 50 50 50 50 50 50 50 50 50 4 4 4 4 4 4 4 4 4 V
A
Precautions
* * * Please be careful of the following: Soldering temperature: 260C max, soldering time: 3 s max (soldering portion of lead: up to 2 mm from the body of the device) If the lead is formed, the lead should be formed up to 5 mm from the body of the device without forming stress to the resin. Soldering should be performed after lead forming. This visible LED lamp also emits some IR light. If a photodetector is located near the LED lamp, please ensure that it will not be affected by this IR light.
2
2005-09-13
TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
TLRE50T(F)
IF - VF
100 Ta = 25C 50 30 10000 Ta = 25C
IV - IF
IF (mA)
(mcd) Luminous intensity IV
1.7 1.8 1.9 2.0 2.1 2.2 2.3 1000 100 10 1
Forward current
10
5 3
1 1.6
10
100
Forward voltage VF
(V)
Forward current
IF (mA)
IV - Tc
3 1.0
Relative luminous intensity - Wavelength
IF = 20 mA
Relative luminous intensity IV
Ta = 25C
Relative luminous intensity
-20 0 60 80
0.8
1
0.6
0.5 0.3
0.4
0.2
0.1
20
40
0 580
600
620
640
660
680
700
Case temperature
Tc
(C)
Wavelength
(nm)
Radiation pattern
80
IF - Ta
Allowable forward current IF
(mA)
60 40 60 70 80 90 1.0 20 0 0
Ta = 25C
20 30 40 50 60 70 80 90
10
0
10
20 30 40 50
0
0.2
0.4
0.6
0.8
20
40
60
80
100
120
Ambient temperature
Ta
(C)
3
2005-09-13
TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
TLRME50T(F)
IF - VF
100 Ta = 25C 50 30 10000 Ta = 25C
IV - IF
IF (mA)
(mcd) Luminous intensity IV
1.7 1.8 1.9 2.0 2.1 2.2 2.3 1000 100 10 1
Forward current
10
5 3
1 1.6
10
100
Forward voltage VF
(V)
Forward current
IF (mA)
IV - Tc
10 1.0
Relative luminous intensity - Wavelength
IF = 20 mA
Relative luminous intensity IV
5
Ta = 25C
Relative luminous intensity
-20 0 20 40 60 80
0.8
3
0.6
1 0.5 0.3
0.4
0.2
0.1
0 580
600
620
640
660
680
700
Case temperature
Tc
(C)
Wavelength
(nm)
Radiation pattern
80
IF - Ta
Allowable forward current IF
(mA)
60 40 60 70 80 90 1.0 20 0 0
Ta = 25C
20 30 40 50 60 70 80 90
10
0
10
20 30 40 50
0
0.2
0.4
0.6
0.8
20
40
60
80
100
120
Ambient temperature
Ta
(C)
4
2005-09-13
TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
TLSE50T(F)
IF - VF
100 Ta = 25C 50 30 10000 Ta = 25C
IV - IF
IF (mA)
(mcd) Luminous intensity IV
1.7 1.8 1.9 2.0 2.1 2.2 2.3 1000 100 10 1
Forward current
10
5 3
1 1.6
10
100
Forward voltage VF
(V)
Forward current
IF (mA)
IV - Tc
3 1.0
Relative luminous intensity - Wavelength
IF = 20 mA
Relative luminous intensity IV
Ta = 25C
Relative luminous intensity
-20 0 60 80
0.8
1
0.6
0.5 0.3
0.4
0.2
0.1
20
40
0 560
580
600
620
640
660
680
Case temperature
Tc
(C)
Wavelength
(nm)
Radiation pattern
80
IF - Ta
Allowable forward current IF
(mA)
60 40 60 70 80 90 1.0 20 0 0
Ta = 25C
20 30 40 50 60 70 80 90
10
0
10
20 30 40 50
0
0.2
0.4
0.6
0.8
20
40
60
80
100
120
Ambient temperature
Ta
(C)
5
2005-09-13
TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
TLOE50T(F)
IF - VF
100 Ta = 25C 50 30 30000 Ta = 25C 10000
IV - IF
IF (mA)
10
Luminous intensity IV
1.7 1.8 1.9 2.0 2.1 2.2 2.3
Forward current
(mcd)
1000
5 3
1 1.6
100 1
10
100
Forward voltage VF
(V)
Forward current
IF (mA)
IV - Tc
3 1.0
Relative luminous intensity - Wavelength
IF = 20 mA
Relative luminous intensity IV
Ta = 25C
Relative luminous intensity
-20 0 60 80
0.8
1
0.6
0.5 0.3
0.4
0.2
0.1
20
40
0 540
560
580
600
620
640
660
Case temperature
Tc
(C)
Wavelength
(nm)
Radiation pattern
80
IF - Ta
Allowable forward current IF
(mA)
60 40 60 70 80 90 1.0 20 0 0
Ta = 25C
20 30 40 50 60 70 80 90
10
0
10
20 30 40 50
0
0.2
0.4
0.6
0.8
20
40
60
80
100
120
Ambient temperature
Ta
(C)
6
2005-09-13
TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
TLYE50T(F)
IF - VF
100 Ta = 25C 50 30 10000 Ta = 25C
IV - IF
IF (mA)
(mcd) Luminous intensity IV
1.7 1.8 1.9 2.0 2.1 2.2 2.3 1000 100 10 1
Forward current
10
5 3
1 1.6
10
100
Forward voltage VF
(V)
Forward current
IF (mA)
IV - Tc
3 1.0
Relative luminous intensity - Wavelength
IF = 20 mA
Relative luminous intensity IV
Ta = 25C
Relative luminous intensity
-20 0 60 80
0.8
1
0.6
0.5 0.3
0.4
0.2
0.1
20
40
0 540
560
580
600
620
640
660
Case temperature
Tc
(C)
Wavelength
(nm)
Radiation pattern
80
IF - Ta
Allowable forward current IF
(mA)
60 40 60 70 80 90 1.0 20 0 0
Ta = 25C
20 30 40 50 60 70 80 90
10
0
10
20 30 40 50
0
0.2
0.4
0.6
0.8
20
40
60
80
100
120
Ambient temperature
Ta
(C)
7
2005-09-13
TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
TLPYE50T(F)
IF - VF
100 Ta = 25C 50 30 10000 Ta = 25C
IV - IF
IF (mA)
Luminous intensity IV
1.7 1.8 1.9 2.0 2.1 2.2
(mcd)
1000 100 20 1
Forward current
10
5 3
1 1.6
2.3
10
100
Forward voltage VF
(V)
Forward current
IF (mA)
IV - Tc
10 1.0
Relative luminous intensity - Wavelength
IF = 20 mA Ta = 25C
Relative luminous intensity IV
Relative luminous intensity
-20 0 20 40 60 80
5 3
0.8
0.6
1
0.5 0.3
0.4
0.2
0.1
0 540
560
580
600
620
640
660
Case temperature
Tc
(C)
Wavelength
(nm)
Radiation pattern
80
IF - Ta
Allowable forward current IF
(mA)
60 40 60 70 80 90 1.0 20 0 0
Ta = 25C
20 30 40 50 60 70 80 90
10
0
10
20 30 40 50
0
0.2
0.4
0.6
0.8
20
40
60
80
100
120
Ambient temperature
Ta
(C)
8
2005-09-13
TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
TLGE50T(F)
IF - VF
100 Ta = 25C 50 30 5000 Ta = 25C
IV - IF
IF (mA)
(mcd) Luminous intensity IV
1.7 1.8 1.9 2.0 2.1 2.2 2.3
1000
Forward current
10
5 3
100
1 1.6
10 1
10
100
Forward voltage VF
(V)
Forward current
IF (mA)
IV - Tc
10 1.0
Relative luminous intensity - Wavelength
IF = 20 mA
Relative luminous intensity IV
5
Ta = 25C
Relative luminous intensity
-20 80
0.8
3
0.6
1 0.5 0.3
0.4
0.2
0.1
0
20
40
60
0 520
540
560
580
600
620
640
Case temperature
Tc
(C)
Wavelength
(nm)
Radiation pattern
80
IF - Ta
Allowable forward current IF
(mA)
60 40 60 70 80 90 1.0 20 0 0
Ta = 25C
20 30 40 50 60 70 80 90
10
0
10
20 30 40 50
0
0.2
0.4
0.6
0.8
20
40
60
80
100
120
Ambient temperature
Ta
(C)
9
2005-09-13
TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
TLFGE50T(F)
IF - VF
100 Ta = 25C 50 30 5000 Ta = 25C
IV - IF
IF (mA)
(mcd) Luminous intensity IV
1.7 1.8 1.9 2.0 2.1 2.2
1000
Forward current
10
5 3
100
1 1.6
2.3
10 1
10
100
Forward voltage VF
(V)
Forward current
IF (mA)
IV - Tc
10 1.0
Relative luminous intensity - Wavelength
IF = 20 mA Ta = 25C
Relative luminous intensity IV
Relative luminous intensity
-20
5 3
0.8
0.6
1
0.4
0.5 0.3
0.2
0.1
0
20
40
60
80
0 520
540
560
580
600
620
640
Case temperature
Tc
(C)
Wavelength
(nm)
Radiation pattern
80
IF - Ta
Allowable forward current IF
(mA)
60 40 60 70 80 90 1.0 20 0 0
Ta = 25C
20 30 40 50 60 70 80 90
10
0
10
20 30 40 50
0
0.2
0.4
0.6
0.8
20
40
60
80
100
120
Ambient temperature
Ta
(C)
10
2005-09-13
TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
TLPGE50T(F)
IF - VF
100 Ta = 25C 50 30 10000 Ta = 25C
IV - IF
IF (mA)
(mcd) Luminous intensity IV
1.7 1.8 1.9 2.0 2.1 2.2 2.3 1000 100 10 1
Forward current
10
5 3
1 1.6
10
100
Forward voltage VF
(V)
Forward current
IF (mA)
IV - Tc
10 1.0
Relative luminous intensity - Wavelength
IF = 20 mA
Relative luminous intensity IV
5
Ta = 25C
Relative luminous intensity
-20 0 20 40 60 80
0.8
3
0.6
1 0.5 0.3
0.4
0.2
0.1
0 520
540
560
580
600
620
640
Case temperature
Tc
(C)
Wavelength
(nm)
Radiation pattern
80
IF - Ta
Allowable forward current IF
(mA)
60 40 60 70 80 90 1.0 20 0 0
Ta = 25C
20 30 40 50 60 70 80 90
10
0
10
20 30 40 50
0
0.2
0.4
0.6
0.8
20
40
60
80
100
120
Ambient temperature
Ta
(C)
11
2005-09-13
TL(RE,RME,SE,OE,YE,PYE,GE,FGE,PGE)50T(F)
12
2005-09-13


▲Up To Search▲   

 
Price & Availability of TLRE50T

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X